Nosso grupo organiza mais de 3.000 Séries de conferências Eventos todos os anos nos EUA, Europa e outros países. Ásia com o apoio de mais 1.000 Sociedades e publica mais de 700 Acesso aberto Periódicos que contém mais de 50.000 personalidades eminentes, cientistas de renome como membros do conselho editorial.

Periódicos de acesso aberto ganhando mais leitores e citações
700 periódicos e 15 milhões de leitores Cada periódico está obtendo mais de 25.000 leitores

Indexado em
  • Índice Copérnico
  • Google Scholar
  • Sherpa Romeu
  • Abra o portão J
  • Genâmica JournalSeek
  • Chaves Acadêmicas
  • Biblioteca de Periódicos Eletrônicos
  • RefSeek
  • Universidade Hamdard
  • EBSCO AZ
  • OCLC – WorldCat
  • Catálogo online SWB
  • Biblioteca Virtual de Biologia (vifabio)
  • Publons
  • Euro Pub
Compartilhe esta página

Abstrato

A Parametric Study of the Effect of Building Distributions and Size on the Propagation of Sound in the Urban Environment

Mostafa Refat A Ismail*

The net effect at a location deep in the urban fabric of noise arising from the operation of multiple distant sources can be expected to be a function of the building density and typical size of buildings in this area. However, little is known as to how these characteristics of the urban fabric affect noise propagation. In this paper sound propagation through a distributed array of medium sized simple building forms has been investigated, assuming that building faces produce perfect diffusion. The method adopted was to calculate the energy exchange between facades assuming hemispherical propagation from a point located at the centre of the illuminated area of a facade. Thus, the energy exchange between faces is replaced by arrays of point sources located on each face.

For the very regular street configuration employed in the model, it was found that there was a strong channelling effect when the source was located between facades lining a street.

The propagation of sound across a more irregular fabric configuration as a function of building density, building ground floor dimensions and building height was investigated. It was found that the sound attenuation rates for each configuration are linear and virtually identical at approximately 52dB per decade. However, for each configuration there are differences in levels at a particular location that can be attributed to the near field effect of local occlusion in the vicinity of the source. The similar attenuation rates suggest that after the initial occlusion effect has determined the amount of sound energy that progresses to the far field, the effect of occlusion for a higher building density is compensated for by reflections from the facades.

Isenção de responsabilidade: Este resumo foi traduzido usando ferramentas de inteligência artificial e ainda não foi revisado ou verificado.