ISSN: 2155-6199

Jornal de Biorremediação e Biodegradação

Acesso livre

Nosso grupo organiza mais de 3.000 Séries de conferências Eventos todos os anos nos EUA, Europa e outros países. Ásia com o apoio de mais 1.000 Sociedades e publica mais de 700 Acesso aberto Periódicos que contém mais de 50.000 personalidades eminentes, cientistas de renome como membros do conselho editorial.

Periódicos de acesso aberto ganhando mais leitores e citações
700 periódicos e 15 milhões de leitores Cada periódico está obtendo mais de 25.000 leitores

Indexado em
  • Índice de Fonte CAS (CASSI)
  • Índice Copérnico
  • Google Scholar
  • Sherpa Romeu
  • Abra o portão J
  • Genâmica JournalSeek
  • Chaves Acadêmicas
  • JornalTOCs
  • PesquisaBíblia
  • Infraestrutura Nacional de Conhecimento da China (CNKI)
  • Diretório de Periódicos de Ulrich
  • Acesso à Pesquisa Online Global em Agricultura (AGORA)
  • RefSeek
  • Universidade Hamdard
  • EBSCO AZ
  • OCLC – WorldCat
  • Catálogo online SWB
  • Publons
  • Fundação de Genebra para Educação e Pesquisa Médica
  • MIAR
  • ICMJE
Compartilhe esta página

Abstrato

Critical Analysis of Two Respirometric Methods for Solid Substrates Based On Continuous and Semi-Continuous Aeration

Rada EC, Ragazzi M and Venturi M

In the sector of respirometry applied to solid waste many tools are available. Moreover, methods for assessing the oxygen consumption can be significantly different. In Italy, the sector is characterized by the adoption of dynamic approaches that are preferred to the static ones. In this paper, a comparison between the two respirometers more adopted in Italy is presented. The first one is the Costech respirometer, with continuous aeration and without temperature control. The second one is the AIR-nl respirometer, with temperature control and a semicontinuous aeration based on the principle of avoiding limiting conditions of oxygen. Results were obtained during an experimental research that involved on one hand the construction of an analytical model for evaluating the Respirometric Index (RI) for various substrates and on the other, the critical analysis of the obtained measurements. In this paper, the relationship between the output of tests conducted in parallel with two different instruments on the same samples is analyzed. Some differences between the results of the measurements and obtainable parameters (RI24) are underlined. Considerations on reference moisture, temperature role, and respirometric index calculation method allow the understanding of the characteristics of the two methods in more detail.