Nosso grupo organiza mais de 3.000 Séries de conferências Eventos todos os anos nos EUA, Europa e outros países. Ásia com o apoio de mais 1.000 Sociedades e publica mais de 700 Acesso aberto Periódicos que contém mais de 50.000 personalidades eminentes, cientistas de renome como membros do conselho editorial.

Periódicos de acesso aberto ganhando mais leitores e citações
700 periódicos e 15 milhões de leitores Cada periódico está obtendo mais de 25.000 leitores

Indexado em
  • Índice Copérnico
  • Google Scholar
  • Sherpa Romeu
  • Abra o portão J
  • Genâmica JournalSeek
  • Infraestrutura Nacional de Conhecimento da China (CNKI)
  • Biblioteca de Periódicos Eletrônicos
  • RefSeek
  • Universidade Hamdard
  • EBSCO AZ
  • OCLC – WorldCat
  • Catálogo online SWB
  • Biblioteca Virtual de Biologia (vifabio)
  • Publons
  • Fundação de Genebra para Educação e Pesquisa Médica
  • Euro Pub
  • ICMJE
Compartilhe esta página

Abstrato

Evaluation of a New Metal Biliary Stent 12 Mm in Diameter: A Case Control Study

Fabrice Caillol, Claire Decoster, Christophe Zemmour, Jerome Winkler, Antoine Debourdeau, Erwan Bories, Jean Phillippe Ratone, Christian Pesenti, Jean Marie Boher, Marc Giovannini

Introduction: Currently, by expert agreement, the diameter of metal biliary stents is 10 mm. New 12 mm diameter stents are now available. The aim of our study was to compare whether the patency of 12 mm diameter stents is better than that of conventional 10 mm diameter stents.

Methods: From April 2017 to April 2018, patients with biliary strictures were treated with metal biliary stents, covered or uncovered, 12 mm in diameter. Control patients treated with stents 10 mm in diameter were identified in our center database. The primary endpoint was time to RBO (recurrent biliary obstruction).

Results: We included 24 patients in the 12 mm group (62.5% male; mean age 71 years old) and 48 patients in the control group (64.6% male; mean age 68.8 years old). The median time to RBO was 5.9 months in the 12 mm group vs. 8.3 months in the 10 mm group (p=0.28). In the malignant stricture subgroup, RBO occurred after 6.1 months and 17.1 months in the 12 mm and 10 mm groups, respectively (p=0.06). The adverse event rate in the month following biliary stent placement was 25% (n=6/24) in the 12 mm group and 2% (n=1/48) in the control group.

Conclusion: This case control study did not show better patency of uncovered 12 mm diameter metal biliary stents in cases of malignant stenosis. The placement of covered 12 mm diameter stents in cases of benign strictures should be better evaluated.

Isenção de responsabilidade: Este resumo foi traduzido usando ferramentas de inteligência artificial e ainda não foi revisado ou verificado.