ISSN: 2278-0238

Revista Internacional de Pesquisa e Desenvolvimento em Farmácia e Ciências da Vida

Acesso livre

Nosso grupo organiza mais de 3.000 Séries de conferências Eventos todos os anos nos EUA, Europa e outros países. Ásia com o apoio de mais 1.000 Sociedades e publica mais de 700 Acesso aberto Periódicos que contém mais de 50.000 personalidades eminentes, cientistas de renome como membros do conselho editorial.

Periódicos de acesso aberto ganhando mais leitores e citações
700 periódicos e 15 milhões de leitores Cada periódico está obtendo mais de 25.000 leitores

Abstrato

Evaluation of granules made using a high-shear mixer granulator in comparison to large model granules

Angeliki Siamidi

The majority of prescriptions dispensed in pharmacies are for oral solid dosage forms such as tablets, capsules or sachets. These are manufactured on an industrial scale using highly specialised machinery and processes. Several scientists have tried in the past to simplify these processes by incorporating new techniques. The main objective of this study was to evaluate the granules made using a high shear mixer granulator in comparison with larger model granules, tablets and beams. While tablets are solid preparations each containing a single dose of one or more active substances and usually obtained by compressing uniform volumes of particles, beams are geometrically simple specimens that are made from powders or granules by compaction (the typical length of the beams is at least ten times their cross-sectional dimension). Beams and tablets were produced using the same granulation mixture (excipients used: lactose and microcrystalline cellulose in a ratio 1:1 and polyvinylpyrrolidone in concentrations of 0.6% solution) and their fracture mechanics were compared. The resistance to crushing or otherwise the tensile strength is the force that is required to fracture the specimen; along its thickness when referring to a beam or the diameter if the specimen is circular. Therefore, the mechanical properties of compacts were evaluated using three-point beam bending experiments and diametric compression tablet tests. The results suggested that the fracture mechanics of the beams were similar to those of the tablets. Therefore, a prediction of the fracture mechanics of the tablets could be easily estimated prior to their manufacturing, only by knowing the fracture mechanics of the corresponding beams. This research was carried out under the guidance of Prof Fridrun Podczeck at the University of Sunderland.