Nosso grupo organiza mais de 3.000 Séries de conferências Eventos todos os anos nos EUA, Europa e outros países. Ásia com o apoio de mais 1.000 Sociedades e publica mais de 700 Acesso aberto Periódicos que contém mais de 50.000 personalidades eminentes, cientistas de renome como membros do conselho editorial.

Periódicos de acesso aberto ganhando mais leitores e citações
700 periódicos e 15 milhões de leitores Cada periódico está obtendo mais de 25.000 leitores

Indexado em
  • Índice Copérnico
  • Google Scholar
  • Sherpa Romeu
  • Abra o portão J
  • Genâmica JournalSeek
  • Infraestrutura Nacional de Conhecimento da China (CNKI)
  • Biblioteca de Periódicos Eletrônicos
  • RefSeek
  • Universidade Hamdard
  • EBSCO AZ
  • OCLC – WorldCat
  • Catálogo online SWB
  • Biblioteca Virtual de Biologia (vifabio)
  • Publons
  • Fundação de Genebra para Educação e Pesquisa Médica
  • Euro Pub
  • ICMJE
Compartilhe esta página

Abstrato

Evaluation of the Portable THD� Anopress Device in Patients with Faecal Incontinence

Cosimo Alex Leo, Jamie Murphy, Emanuel Cavazzoni, Gregory P Thomas, Shafaque Shaikh, Jonathan D Hodgkinson, Janindra Warusavitarne and Carolynne J Vaizey

Background: THD Anopress® has been promoted as a new portable anal manometer providing measurements of whole anal canal pressures. This study aims to report the anorectal function of patients suffering from Faecal Incontinence (FI) using this new device and the associated patient comfort.
Methods: We reviewed data from patients suffering from FI who had been evaluated with the Anopress. The St Mark’s score had been routinely used to evaluate the severity of FI. Manometric parameters and pressures were evaluated. Acceptability of this test was also assessed using the Visual Analogue Scale (VAS).
Results: THD Anopress® device was used to assess 60 patients with FI. The median baseline St Mark’s FI score was 14 (7-24). A mixed FI was seen in 34 (57%) patients. Resting pressures were 25 (0-60) in the female group and 30 (0-52) mmHg in the male group. Maximum squeeze increments were 27 (6-106) in the female and 42 (6-99) mmHg in male subject group. Maximum endurance squeeze in 10 seconds were 32 (5-89) in the female and 31 (10-65) mmHg in the male groups. Involuntary maximum squeeze was 33 (6-103) in the female group and 27 (7-90) mmHg in the male group. These values were significantly reduced when compared to previously report normative values. The median VAS is of 0 at insertion and during the procedure.
Conclusion: The THD Anopress® device appears to detect anal sphincter dysfunction in those with symptomatic FI and is well tolerated.