Nosso grupo organiza mais de 3.000 Séries de conferências Eventos todos os anos nos EUA, Europa e outros países. Ásia com o apoio de mais 1.000 Sociedades e publica mais de 700 Acesso aberto Periódicos que contém mais de 50.000 personalidades eminentes, cientistas de renome como membros do conselho editorial.

Periódicos de acesso aberto ganhando mais leitores e citações
700 periódicos e 15 milhões de leitores Cada periódico está obtendo mais de 25.000 leitores

Indexado em
  • Índice Copérnico
  • Google Scholar
  • Abra o portão J
  • Genâmica JournalSeek
  • PesquisaBíblia
  • Biblioteca de Periódicos Eletrônicos
  • RefSeek
  • Universidade Hamdard
  • EBSCO AZ
  • OCLC – WorldCat
  • Catálogo online SWB
  • Biblioteca Virtual de Biologia (vifabio)
  • Publons
  • Fundação de Genebra para Educação e Pesquisa Médica
  • ICMJE
Compartilhe esta página

Abstrato

Interventional Cardiology-Eight Years of Practice: Do Increased Experience and Technological Evolution Lead to Undertaking More Difficult Cases and Higher Patient Doses?

Tsapaki V, Kottou S, Fotos N, Nikolopoulos D and Patsilinakos S

In our dedicated catheterization laboratory, within the years 2009–2016, 8286 Interventional Cardiology (IC) procedures were performed by two interventional cardiologists with more than 10 years of experience. There were 5469 Coronary Angiographies (CA) and 2817 Percutaneous Coronary Interventions (PCI). The purpose was to analyze annual patient radiation data, investigate trends and compare with national and international literature and Dose Reference Levels (DRL). Patient doses were determined in terms of: kerma-area product PKA, fluoroscopy time FT and reference air-kerma Ka,r. Concerning the number of frames F, in 1.8% of CA cases and in 40% of PCI cases, was higher than Greek DRLs. PKA, in 13% of CA cases and in 31% of PCI cases, was higher than Greek DRLs. In 0.4% of CA cases, the calculated effective dose values were higher than 40 mSv, whereas in 0.9% PCI cases higher than 80 mSv. In 0.2% of CA cases, PSD was higher than 2 Gy and in 0.04% cases higher than 3 Gy. In 13% of PCI cases, PSD was higher than 2 Gy, in 3% higher than 3 Gy and in 0.4% higher than 5 Gy. FT in 19.2% of CA cases and in 32% of PCI cases was higher than Greek DRLs. The radiation dose trends in IC procedures in this hospital, for the last 8 years, suggest that patient radiation doses in CA are less variable through the years compared to PCI. Doses are comparable to the literature and median values are lower than Greek and European DRLs. The practice of the well experienced interventionalists, with the support of evolving technology, shows that simpler procedures, like CA, need slight shorter FT, while the most demanding procedures like PCI, appear to require more frames without increasing in FT or PSD.