ISSN: 2161-0681

Jornal de Patologia Clínica e Experimental

Acesso livre

Nosso grupo organiza mais de 3.000 Séries de conferências Eventos todos os anos nos EUA, Europa e outros países. Ásia com o apoio de mais 1.000 Sociedades e publica mais de 700 Acesso aberto Periódicos que contém mais de 50.000 personalidades eminentes, cientistas de renome como membros do conselho editorial.

Periódicos de acesso aberto ganhando mais leitores e citações
700 periódicos e 15 milhões de leitores Cada periódico está obtendo mais de 25.000 leitores

Indexado em
  • Índice Copérnico
  • Google Scholar
  • Sherpa Romeu
  • Abra o portão J
  • Genâmica JournalSeek
  • JornalTOCs
  • Diretório de Periódicos de Ulrich
  • RefSeek
  • Universidade Hamdard
  • EBSCO AZ
  • OCLC – WorldCat
  • Publons
  • Fundação de Genebra para Educação e Pesquisa Médica
  • Euro Pub
  • ICMJE
Compartilhe esta página

Abstrato

Xylene/Chloroform Free Microwave Tissue Processing and Staining a Non-hazardous and Time Effective Alternative

Swaroop Raj1, Divya C and Harendra Kumar

Introduction: Tissue processing using xylene/chloroform has been employed in histopathology reporting for the past 100 years. Microwave technique has not only reduced the processing time from 1 day to one hour but also doesn’t use xylene/chloroform and has been found to be on par with conventional processing. Xylene is expensive and detrimental to human health. The present study replaces chloroform with isopropanolol in tissue processing and xylene with liquid dish wash solution (LDW) in staining which is not only cheap but also non bio hazardous.
Aim:
To assess the efficacy of xylene free processing (microwave) and staining versus conventional tissueprocessing and hematoxylin and eosin are staining.
Materials and methods:
Two Tissue bits from 15 consecutively submitted samples at RL Jalappa Hospital after 1st Jan 2015 each of breast, cervix, lymph node, fat, thyroid, skin, alimentary tract, muscle, salivary gland, liver and kidney were taken and one was processed and stained using conventional method, other using xylene/chloroform free processing and conventional staining and other with both xylene/chloroform free processing and staining. The 495 sections were evaluated and scored by two pathologists independently for nuclear staining, cytoplasmic staining, uniformity, clarity and crispness.
Results:
In the samples evaluated xylene free processing and staining seems to be on par with conventional xylene processed and stained sections terms of nuclear and cytoplasmic detail, clarity and crispness. However Xylene cleared sections showed slightly better uniform staining (p value->0.05)
Conclusion:
Xylene/chloroform free processing and staining is not only a rapid but also safe alternative to conventional processing and staining using xylene. However more extensive studies need to be done on other types of tissues for validation

Isenção de responsabilidade: Este resumo foi traduzido usando ferramentas de inteligência artificial e ainda não foi revisado ou verificado.